Cooling Fan, Temperature Control Unit Support Cabinet, Rack

Product Details
Customization: Available
Customized: Non-Customized
Certification: RoHS, CCC, ISO9001
Still deciding? Get samples of US$ 35/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
86
Year of Establishment
2011-01-14
  • Cooling Fan, Temperature Control Unit Support Cabinet, Rack
  • Cooling Fan, Temperature Control Unit Support Cabinet, Rack
  • Cooling Fan, Temperature Control Unit Support Cabinet, Rack
  • Cooling Fan, Temperature Control Unit Support Cabinet, Rack
  • Cooling Fan, Temperature Control Unit Support Cabinet, Rack
  • Cooling Fan, Temperature Control Unit Support Cabinet, Rack
Find Similar Products

Basic Info.

Model NO.
Temperature Control Unit
Display Type
LCD
Material
Steel
MOQ
30
Transport Package
Box
Specification
1U
Trademark
Turn-Link
Origin
Zhejiang, China

Product Description






Digital Temperature Unit 
I Size : 1U 19inch
II Technical Parameters:
Input: 150V~265VAC 47~63Hz Output: 150V~265VAC 47~63Hz 13A
III Instructions
Cooling Fan, Temperature Control Unit Support Cabinet, Rack
3.1 Proper working display :
Real -time clock, the current temperature, fan state are showed on the display;
3.2 Temperature setting status display:
1. Press the "+" key to display the setting temperature of upper limit;  press "-" to display the setting temperature of lower limit; 
2.Pressing the "Temp" more than 3 seconds to enter modify mode of the temperature parameters, display "Set Tem" at the same time,then press "Temp" in turn display F1~F6 parameter value,and press the"+""-"key can modify the current F1~F6 parameter values.
3.Once setting up completed, press the "Temp" button more than 3 seconds, return to the normal display status.
Function Menu:
ITEMS FUNCTION SETTING RANGE UNIT Default
F1 Upper limit F2~60 ºC 25
F2 Lower limit -40~F1 ºC 15
F3 Temperature calibration -5~5 ºC 0.0
F4 Output protection time 0~9 Min 3
F5 Exceeding temperature offset 0~50 ºC 5.0
F6 Exceeding temperature alarm delay time 0~99 Min 5
F1:Temperature upper limit:when the actual temperature is higher than the setting temperature alue,the fan start automatically.
F2:Temperature lower limit:when the actual temperature is lower than the temperature,the fan stop.
F3:Temperature calibration :When the measuring temperature value and the actual real temperature deviate,it will correct the temperature with this calibration value,in order to achieve the measurement accuracy.
F4:Output protection time:When the fan start-up, it has to run continuously for this time value to stop.
F5:Exceeding temperature offset:The default actual temperature value beyond the upper limit or below the lower limit temperature value.
F6:Exceeding temperature alarm delay time:When the actual temperature beyond the temperature value "F1+F5",or below the temperature value "F2-F5",the delay buzzer alarm.
4.Clock setting:
Pressing "Time" button more than 3 secondsto enterthe state of the clock Settings, then press the "Temp" key switch in turn to set the correct time "hour", "minute", "seconds" state, press "+", "-" button to set the current clock.
IV  Alarm instructions:
When actualtemperature is higher than set temperature F1 + F5 Value or lower than set F2 -F5.value, the alarm indicator start flashing, after the setting time "F6", the buzzer starts alerting until the temperature is adjusted to the normal temperature.
 